HL7 V2 Laboratory Input

Use the experimental laboratory adapter only for the registered GLIMS OUL^R21/HL7 V2 2.4 and OUL^R22/HL7 V2 2.5 contracts. It produces an EU Lab 2.1.0 R4 document through explicit technical-edge, logical and target StructureMaps. It does not register generic V2 conversion or additional FHIR profile pairs.

Discover the contract

Need Endpoint or value
Transform POST /fhir/r4/$transform
Lab alias POST /fhir/hl7v2-r4/$transform
CapabilityStatement GET /fhir/hl7v2-r4/metadata
OperationDefinition GET /fhir/hl7v2-r4/OperationDefinition/glims-lab-transform
Source contracts urn:cumuluz:hl7v2:GLIMS:OUL-R21:2.4, urn:cumuluz:hl7v2:GLIMS:OUL-R22:2.5
Target profile http://hl7.eu/fhir/laboratory/StructureDefinition/Bundle-eu-lab\|2.1.0

Send original bytes

JSON requests use R4 Parameters with a source Binary of content type x-application/hl7-v2+er7 and base64-encoded original ER7 bytes. Supply the target canonical with valueCanonical. An omitted sourceProfile selects the exact registered contract from MSH. An explicit source canonical must match the header; R21/2.5 and R22/2.4 are not registered. Optional timeZone is a string, defaulting to Europe/Amsterdam for timestamps without an offset. validationMode accepts report or enforce; returnLogical is a Boolean.

Alternatively send a multipart source file on either lab-capable endpoint:

curl -sS \
  -H 'Accept: application/fhir+json' \
  -F 'source=@input.hl7;type=x-application/hl7-v2+er7' \
  -F 'targetProfile=http://hl7.eu/fhir/laboratory/StructureDefinition/Bundle-eu-lab|2.1.0' \
  -F 'validationMode=enforce' \
  'http://localhost:8080/fhir/r4/$transform'

The alias can omit targetProfile because it has a single target; /fhir/r4/$transform requires it. Multipart primitive fields use their parameter names and plain values. Duplicate or unknown fields, unsupported transfer encodings, non-file sources and wrong part media types fail with HTTP 400. The complete request limit includes multipart overhead; oversized requests fail with 413. This is an alternative representation of the same operation.

Retain the supplied bytes and MSH-18 character set. The adapter supports ASCII, UTF-8 and ISO-8859-15 according to the source contract. Re-encoding a file before submission can change its meaning and source identity.

Interpret the response

HTTP 200 returns R4 Parameters with:

Parameter Meaning
result R4 document Bundle with EU Lab Composition, report and structured entries
targetProfile selected EU Lab Bundle canonical
outcome mapping/validation diagnostics; inspect all error and fatal issues
source Binary retaining the original message bytes
profileAssessment independent extra-profile assessment for each applicable resource
mappingEvidence source/target maps and edge/logical validation; optional Binary intermediates with returnLogical=true

This edge response uses mappingEvidence, rather than the FHIR profile-pair translationReport. A returned resource does not establish successful validation in report mode. Extra NL Core/GBB claims require successful unrelaxed validation; the adapter does not copy claims from examples.

DiagnosticReport.presentedForm includes a generated text Attachment alongside the structured results. Its contentType is text/plain; charset=utf-8; decode data as base64 and then UTF-8. The title and text identify it as generated from the supplied message. It is not an original laboratory document. Report issue time is retained when supplied; no current clinical timestamp is invented.

R21 and R22 source boundaries

The header selects one of two registered GLIMS contracts. R21 and R22 are message structures; 2.4 and 2.5 are HL7 standard versions. These are exact GLIMS source subsets, not a generic converter for all laboratory messages.

Field or behavior R21 / 2.4 R22 / 2.5
Result values Numeric NM and simple scalar SN, with a nonempty value Same numeric values plus literal scalar ST, including blood group and rhesus text
OBX-11 status F, C, P, R F, C, P, R, plus I without a value
Pending results Rejected by this contract I becomes registered with temp-unknown dataAbsentReason; value[x] is absent
Specimens Separate OBR occurrences; no inferred shared specimen identity Namespace-qualified SPM-2 identities; a specimen can be shared by multiple orders in its SPM group
Order control and timing ORC precedes OBR; OBR-27 or ORC-7 timing ORC and optional scalar TQ1 follow their own OBR and precede its results
Clinical dates Second precision, with source offset or configured zone Also preserves day-only dates without inventing a midnight timestamp
Result producer OBX-15 required If absent, the required EU Lab performer Reference carries standard unknown data-absent-reason
Additional patient context Registered PID subset Also PD1-4 general practitioners; PV1 is retained in Binary with field-locator warnings

Source identifiers, demographics, contacts, ordering providers, orders, transaction actors, reference ranges, notes, instruments and analysis dates pass through explicit technical-edge, logical and EU Lab maps. R22 has separate glims-r22-to-logical source maps that import shared normalization groups; this is reuse, not profile inheritance. Both contracts use the same registered EU Lab 2.1.0 target maps.

R22 pending units are retained as explicit notes, not as a fabricated result quantity. ST values remain strings without inferred ABO/Rh codes. A sending facility can identify the document author when there is no result producer; this does not make it the result-producing laboratory. The Dutch CX-5 label NNNLD maps explicitly to the broader NI identifier type, with NNNLD kept in type.text and the source authority/value preserved. No BSN identifier system or verification is inferred. Unconfirmed identifier-type labels remain source-local.

The GLIMS variant permits historical OBR records before the first SPM. This does not establish generic OUL_R22 conformance. Contradictory repeated specimen identities, SPM/OBR type/time/volume conflicts, mismatched order identifiers, displaced/duplicate controls and incompatible value/status combinations fail explicitly. Unsupported precision, complex/repeated values, cancellation/deletion messages, microbiology and unregistered version/message combinations remain outside these contracts.

Local laboratory and alternate code systems stay as supplied unless an explicit confirmed mapping exists. A valid EU Lab document does not establish equivalence to LOINC/SNOMED or earn a Dutch lab-profile claim. Extra source fields and unsupported composite qualifiers remain authoritative in the retained Binary; warning messages identify the field locators without repeating patient values.

Verified R22 case

A synthetic message with five OBR orders, two final ST results, eight pending results, two SPM specimens, post-OBR ORC/TQ1 and day-precision historical dates passes technical-edge, logical and official EU Lab validation. Its source bytes are retained unchanged; the two orders under the second SPM reference the same specimen. A text-only variant also validates with explicit missing-performer reasons. R21 maximal/collision/legacy cases remain covered, including byte-identical output for the deployed R21 reference case.

The repository's docs/HL7V2_LAB.md maintains the detailed field matrix, CLI commands and maximal, collision and legacy cases. FHIR profile-pair integration remains described in Transform; C-CDA uses its separate collection contract.