Cumuluz Translate Implementation Guide
0.1.0 - ci-build
Cumuluz Translate Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-MedicalDeviceProduct | Version: 0.1.0 | |||
| Draft as of 2026-10-29 | Computable Name: XibMedicalDeviceProduct | |||
GBB Device specialization retaining explicit local and legacy mapping additions. The pinned GBB alpha profile is the structural basis.
Usages:
You can also check for usages in the FHIR IG Statistics
Description of Profiles, Differentials, Snapshots and how the different presentations work.
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | ||||||||||
![]() ![]() |
0..1 | uri | A set of rules under which this content was created | ||||||||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | ||||||||||
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | ||||||||||
![]() ![]() |
0..* | Extension | Extensions that cannot be ignored | ||||||||||
![]() ![]() |
0..* | Identifier | Instance identifier
| ||||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization
| ||||||||||
![]() ![]() |
0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable)
| ||||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture
| ||||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device
| ||||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by.
| ||||||||||
![]() ![]() |
0..1 | string | The model number for the device
| ||||||||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices.
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The version text
| ||||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | ||||||||||
![]() ![]() ![]() |
1..1 | markdown | The annotation - text content (as markdown)
| ||||||||||
Documentation for this format | |||||||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from NlcoreDevice
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() |
|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | |
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | |
Documentation for this format | ||||
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | ||||||||||
![]() ![]() |
0..1 | id | Logical id of this artifact | ||||||||||
![]() ![]() |
0..1 | Meta | Metadata about the resource | ||||||||||
![]() ![]() |
0..1 | uri | A set of rules under which this content was created | ||||||||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| ||||||||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | ||||||||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | ||||||||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | ||||||||||
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | ||||||||||
![]() ![]() |
0..* | Extension | Extensions that cannot be ignored | ||||||||||
![]() ![]() |
0..* | Identifier | Instance identifier
| ||||||||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | ||||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | ||||||||||
![]() ![]() ![]() |
0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||||||
![]() ![]() ![]() |
0..1 | string | UDI Human Readable Barcode String | ||||||||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | ||||||||||
![]() ![]() |
0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | ||||||||||
![]() ![]() |
0..1 | string | The distinct identification string | ||||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable)
| ||||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture
| ||||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device
| ||||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by.
| ||||||||||
![]() ![]() |
0..1 | string | The model number for the device
| ||||||||||
![]() ![]() |
0..1 | string | The part number of the device | ||||||||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices.
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | ||||||||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | ||||||||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | ||||||||||
![]() ![]() ![]() |
1..1 | string | The version text
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | ||||||||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | ||||||||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | ||||||||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | ||||||||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | ||||||||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | ||||||||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | ||||||||||
![]() ![]() |
0..1 | uri | Network address to contact device | ||||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | ||||||||||
![]() ![]() ![]() |
0..1 | Individual responsible for the annotation | |||||||||||
![]() ![]() ![]() ![]() |
Reference(Practitioner | Patient | RelatedPerson | Organization) | ||||||||||||
![]() ![]() ![]() ![]() |
string | ||||||||||||
![]() ![]() ![]() |
0..1 | dateTime | When the annotation was made | ||||||||||
![]() ![]() ![]() |
1..1 | markdown | The annotation - text content (as markdown)
| ||||||||||
![]() ![]() |
0..* | CodeableConcept | Safety Characteristics of Device | ||||||||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | ||||||||||
Documentation for this format | |||||||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from NlcoreDevice
Key Elements View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | ||||||||||
![]() ![]() |
0..1 | uri | A set of rules under which this content was created | ||||||||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | ||||||||||
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | ||||||||||
![]() ![]() |
0..* | Extension | Extensions that cannot be ignored | ||||||||||
![]() ![]() |
0..* | Identifier | Instance identifier
| ||||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization
| ||||||||||
![]() ![]() |
0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable)
| ||||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture
| ||||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device
| ||||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by.
| ||||||||||
![]() ![]() |
0..1 | string | The model number for the device
| ||||||||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices.
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device
| ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The version text
| ||||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | ||||||||||
![]() ![]() ![]() |
1..1 | markdown | The annotation - text content (as markdown)
| ||||||||||
Documentation for this format | |||||||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
Differential View
This structure is derived from NlcoreDevice
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() |
|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | |
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | |
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | |
Documentation for this format | ||||
Snapshot View
| Name | Flags | Card. | Type | Description & Constraints Filter: ![]() | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0..* | NlcoreDevice | Item used in healthcare This profile also complies with the profile Device (EPS) | ||||||||||
![]() ![]() |
0..1 | id | Logical id of this artifact | ||||||||||
![]() ![]() |
0..1 | Meta | Metadata about the resource | ||||||||||
![]() ![]() |
0..1 | uri | A set of rules under which this content was created | ||||||||||
![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| ||||||||||
![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation This profile does not constrain the narrative in regard to content, language, or traceability to data elements | ||||||||||
![]() ![]() |
0..* | Resource | Contained, inline Resources | ||||||||||
![]() ![]() |
0..* | Extension | Extension Slice: Unordered, Open by value:url Slicing Note: The rules on this element (including its children) apply to all the slices, but are not repeated in them | ||||||||||
![]() ![]() ![]() |
0..1 | (Complex) | XIB Device Details URL: https://fhir.cumuluz.org/xib/StructureDefinition/xib-DeviceDetails | ||||||||||
![]() ![]() |
0..* | Extension | Extensions that cannot be ignored | ||||||||||
![]() ![]() |
0..* | Identifier | Instance identifier
| ||||||||||
![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | ||||||||||
![]() ![]() |
0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | Mandatory fixed portion of UDI
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization
| ||||||||||
![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | ||||||||||
![]() ![]() ![]() |
0..1 | base64Binary | UDI Machine Readable Barcode String | ||||||||||
![]() ![]() ![]() |
0..1 | string | UDI Human Readable Barcode String | ||||||||||
![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | ||||||||||
![]() ![]() |
0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||||||||
![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | ||||||||||
![]() ![]() |
0..1 | string | The distinct identification string | ||||||||||
![]() ![]() |
0..1 | string | Name of device manufacturer
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date when the device was made
| ||||||||||
![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable)
| ||||||||||
![]() ![]() |
0..1 | string | Lot number of manufacture
| ||||||||||
![]() ![]() |
0..1 | string | Serial number assigned by the manufacturer
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | string | The name of the device
| ||||||||||
![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by.
| ||||||||||
![]() ![]() |
0..1 | string | The model number for the device
| ||||||||||
![]() ![]() |
0..1 | string | The part number of the device | ||||||||||
![]() ![]() |
0..1 | CodeableConcept | The kind or type of device Binding: DeviceType (example): Codes to identify medical devices.
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | ||||||||||
![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual design of the device or software version running on the device
| ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | ||||||||||
![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | ||||||||||
![]() ![]() ![]() |
1..1 | string | The version text
| ||||||||||
![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||||||||
![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | ||||||||||
![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | ||||||||||
![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | ||||||||||
![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | ||||||||||
![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | ||||||||||
![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | ||||||||||
![]() ![]() |
0..1 | Reference(Location) | Where the device is found | ||||||||||
![]() ![]() |
0..1 | uri | Network address to contact device | ||||||||||
![]() ![]() |
0..* | Annotation | Device notes and comments | ||||||||||
![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | ||||||||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | ||||||||||
![]() ![]() ![]() |
0..1 | Individual responsible for the annotation | |||||||||||
![]() ![]() ![]() ![]() |
Reference(Practitioner | Patient | RelatedPerson | Organization) | ||||||||||||
![]() ![]() ![]() ![]() |
string | ||||||||||||
![]() ![]() ![]() |
0..1 | dateTime | When the annotation was made | ||||||||||
![]() ![]() ![]() |
1..1 | markdown | The annotation - text content (as markdown)
| ||||||||||
![]() ![]() |
0..* | CodeableConcept | Safety Characteristics of Device | ||||||||||
![]() ![]() |
0..1 | Reference(Device) | The parent device | ||||||||||
Documentation for this format | |||||||||||||
| Path | Status | Usage | ValueSet | Version | Source |
| Device.language | Base | preferred | Common Languages | 📍4.0.1 | FHIR Std. |
| Device.udiCarrier.entryType | Base | required | UDIEntryType | 📍4.0.1 | FHIR Std. |
| Device.status | Base | required | FHIRDeviceStatus | 📍4.0.1 | FHIR Std. |
| Device.statusReason | Base | extensible | FHIRDeviceStatusReason | 📍4.0.1 | FHIR Std. |
| Device.deviceName.type | Base | required | DeviceNameType | 📍4.0.1 | FHIR Std. |
| Device.type | Base | example | Device Type | 📍4.0.1 | FHIR Std. |
| Id | Grade | Path(s) | Description | Expression |
| dom-2 | error | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources |
contained.contained.empty()
|
| dom-3 | error | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource |
contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
|
| dom-4 | error | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated |
contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
|
| dom-5 | error | Device | If a resource is contained in another resource, it SHALL NOT have a security label |
contained.meta.security.empty()
|
| dom-6 | best practice | Device | A resource should have narrative for robust management |
text.`div`.exists()
|
| ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children |
hasValue() or (children().count() > id.count())
|
| ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both |
extension.exists() != value.exists()
|
This structure is derived from NlcoreDevice